Air compressor selection suggestion

Feb 20, 2023

According to incomplete statistics, the power consumption of the compressor air system accounts for 10%-30% of the electricity consumption of enterprises, and 96% of the energy consumption of the compressed air system is the power consumed by the compressor.
The vast majority of compressors have low efficiency, unsatisfactory equipment operation parameter settings, equipment mismatch, large pipe network pressure loss, unscientific early selection, system leakage, human demand, incorrect use and inappropriate system control, etc. complex issues.
The low-cost strategy of the compressed air system should first start with energy saving and consumption reduction. The air compressor system consumes a lot of manpower and material resources in the procurement and use, including personnel expenses, purchase and installation costs, power consumption and maintenance costs. So how to plan and select the air compressor system in the initial investment to save energy and reduce consumption?

Common unreasonable phenomena in the air compressor system
Selection of air compressor
When purchasing, we only consider the cheap price of the machine, but when we use it, we find that the quality is too poor, the operation is unstable, and the downtime of failure is long, resulting in the loss of production line downtime;
When purchasing, only consider the stability of operation, ignoring the ratio of energy consumption, resulting in huge waste over time;
· Neglecting the quality of the after-sales service of the supplier during procurement, failing to arrive in time for troubleshooting, and inconvenient procurement of spare parts, all of which caused unnecessary losses.

system planning
The capacity of the air compressor is too large, resulting in a high waste of no-load energy for the air compressor;
·Too many filters are installed, resulting in large pressure loss and high energy waste;
·The air compressors are not centrally supplied, but distributed in various parts of the plant, and the pipelines are independent, which not only increases the cost of equipment purchase, but also increases;
·Pipeline costs and operation and maintenance costs;
The ambient temperature of the air compressor room is too high, which is equivalent to reducing the efficiency of the air compressor, the exhaust volume is reduced, and the energy consumption is increased; every 10°C increase in the ambient temperature is equivalent to a decrease in the efficiency of the air compressor by about 3%. The pipeline layout is unreasonable, and there are too many elbow joints, which will increase the pressure loss.

System control and management
The outlet pressure of the air compressor is set too high, resulting in increased energy consumption and waste. For every 1 kg/cm2 increase in pressure, energy consumption increases by about 7%;
Multiple air compressors perform loading and unloading actions at the same time or capacity adjustment (partial load) operation at the same time, which increases energy waste;
The machine is not well maintained or not maintained after the expiration date, small faults accumulate into major faults, and the life of the machine is artificially shortened;
The environment of the machine room is too dirty, resulting in frequent replacement of air compressor filters, oil filters, oil-gas separators and cooling oil;
The precision filter of the pipeline is not replaced in time, resulting in excessive pressure loss and serious energy waste.