The solution to the oily exhaust of the screw air compressor

Feb 20, 2023

Troubleshooting and troubleshooting steps:
When oil is found in the exhaust of the compressor, it is not necessary to dismantle the equipment blindly, but to analyze the causes based on the above, and follow the steps from easy to difficult to determine the location of the fault. This can reduce a lot of repair time and manpower.
When the compressor starts normally and the system reaches the rated pressure, slowly open the exhaust gate valve with the opening as small as possible to allow a small amount of gas to be discharged. At this time, use a dry paper towel to face the exhaust air flow. If the paper towel immediately changes color and has oil droplets, it can be judged that the oil in the exhaust gas of the compressor exceeds the standard. According to the amount of oil in the exhaust and different time periods, etc., the location of the fault can be correctly judged.
When the opening of the exhaust gate valve is increased, it is found that the exhaust airflow is in the form of uninterrupted dense fog, indicating that the airflow has a large oil content, and then check the oil return situation in the sight glass of the oil return pipe. If the oil return from the observation mirror of the oil return pipe increases significantly, it is generally because the separator core is damaged or the cooling oil of the separator is added too much; if there is no oil return from the observation mirror of the oil return pipe, it is generally because the oil return pipe is broken or blocked.
When the opening of the exhaust gate valve is increased, it is found that the front part of the exhaust airflow is in the form of dense fog, and it becomes normal after a while; continue to increase the opening of the exhaust gate valve, open all the exhaust valves, and then observe the system pressure gauge , if the pressure displayed by the pressure gauge is lower than the set pressure of the minimum pressure valve, the exhaust valve will continue to exhaust and the airflow will be in the form of uninterrupted dense fog. When this phenomenon occurs, the fault is generally the failure of the minimum pressure valve.
After normal shutdown, the automatic vent valve will exhaust. If there is a large amount of oil in the exhaust, it means that the automatic vent valve is damaged.