Causes And Treatment Of Overheating Of Compressor

Feb 18, 2023

Compressor overheating may occur in the following situations:
1. The work efficiency is reduced, and the air volume and pressure cannot be reached or cannot be reached on time
2. Increased power consumption and reduced productivity
3. The lubricating oil becomes thinner or even carbonized and coked, which deteriorates the lubrication condition of the compressor, and the residue enters the cylinder block, which increases wear and reduces the seal.
4. What's more, the cylinder is scuffed or blocked seriously, causing equipment damage or explosion.

External causes:
1. The surrounding environment of the compressor affects the heat dissipation of the air compressor
For example, the compressor is too close to a wall or obstacle, there are other heat sources near the compressor, the front door or side door is open when the compressor is running, and the fan cannot form a strong airflow...
2. The machine room is too small, and the compressor needs to work continuously and under heavy load. The cooling, cooling or ventilation did not keep up.
3. The surrounding environment is poor and there is a lot of dust, which causes the equipment to be blocked...

Internal reasons:
1. There is a problem with the device itself.
For example, blocked
2. Too many impurities in the lubricating oil cause the equipment to be blocked
The filter element is saturated or fails but is not replaced in time, causing the equipment to block. . .
3. The piston ring is seriously worn and has not been replaced, and the gasket is damaged, the safety valve is invalid, and the oil-water separator is abnormal and deflated.

solution:
1. Regularly clean the compressor room and the dust of the compressor to ensure that the environment around the compressor is clean.
2. Equip the compressor with corresponding "physical cooling" conditions.
3. Regular maintenance.